Home
Products
About
Solutions
Resources Contact Get Your Quote
902-928mhz or 865-868mhz

Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm for Curved Surface Items and Oxygen Bottle Tank Asset Tracking

NXP U8902-928mhz or 865-868mhz80mm*58mm*3mm

UHF RFID on-metal tag for gas cylinder tracking, with **EPC 96-128bits** and **TID 48 bits** memory, **902-928MHz** or **865-868MHz** frequency, and **3-5m** read range on metal.

50 pieces
MOQ
1–2 pcs (Free) · 5-7 days
Samples
3-5m(On Metal)
Read range
Gas Cylinder UHF RFID On-Metal Tag – Oxygen Bottle Tank Asset Tracking Label
902-928mhz or 865-868mhz
EPC Class1 Gen2/ISO 18000-6C
IP68
Key features

What the Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm does

Main functions

This on-metal RFID tag attaches to gas cylinders so you can track them with a UHF RFID reader. It works with EPC Class1 Gen2/ISO 18000-6C readers and is designed for outdoor use. The tag offers a read range of 3-5m on metal, operates from -20°C to 80°C, and measures 80mm*58mm*3mm.

How it works, in plain words

  1. The tag holds a chip with a unique number and is built with a spacer between its antenna and the metal, so metal does not block it as it does an ordinary tag. It has no battery.
  2. A handheld reader (or a reader at a door or tool counter) sends a signal. Every tagged asset in range answers with its number, including those turned away or behind others.
  3. Your asset register links the number to the item: what it is, where it is, who has it, when it was last checked.

What you need to use it

  • The tags (this product), fixed to each asset. Use an on-metal tag where the item is metal.
  • A handheld reader for audits, and optionally a fixed reader at a door or tool counter.
  • An asset register or maintenance system with the list of assets. A simple list is enough to start. Tell us what you use.

What it looks like in your business

Cylinder fleet managerTrack cylinders in and out

Today: You lose track of which cylinders are on site and which are out with customers. With the product: Apply the tag to each cylinder. As cylinders pass a fixed reader at the gate, their ID is recorded automatically.

What you get: You know where your cylinders are without manual counting.

Safety inspectorQuick cylinder identification

Today: Inspectors waste time reading labels that are damaged or hard to see. With the product: The tag stores a unique ID that can be read from up to 3-5m away with a handheld reader, even if the tag is dirty.

What you get: Inspections are faster and more accurate.

Warehouse operatorAutomated inventory counts

Today: Counting cylinders manually is slow and error-prone. With the product: Use a handheld or fixed reader to scan all tagged cylinders in the storage area. The tag's on-metal design ensures reliable reads.

What you get: Inventory counts are quicker and more reliable.

Maintenance technicianLink maintenance records

Today: Paper records get lost, and it's hard to know a cylinder's service history. With the product: Scan the tag to pull up the cylinder's maintenance history in your system.

What you get: Service records are always accessible.

Before you orderTest on your real metal and your real reader

Today: a data-sheet range is trusted, and then the tag reads poorly on painted or curved metal. With the tag: order a sample, fix it on a real asset in its real position, and read it with your handheld. Check the range and the angle, then order volume.

What you get: A tag proven on your metal.

At a glance

  • Chip: NXP U8
  • Memory: EPC 128bits,
  • Read range: 3-5m(On Metal)
  • Durability: IP68
  • Operating temperature: -20°C to 80°C
  • Installation: Industrial grade adhesive binding, sewing, riveting
  • Customization: Customized logo,QR code, Serial No.
Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm – for Curved Surface Items and Oxygen Bottle Tank Asset Tracking detail 1Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm – for Curved Surface Items and Oxygen Bottle Tank Asset Tracking detail 2
How it works

How to Use It in Your System

System setup

The hardware and software that work with the Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm in a typical project.

  1. 1Tags (this product)

    Fixed to each asset.

  2. 2Reader

    Handheld for audits; optionally fixed at a door or counter.

  3. 3Asset register

    Holds what each number means.

  4. 4Audit

    Compare what is read with what the register expects.

Installation and daily use

  1. List what to tag

    Choose assets that are lost, shared or need inspection. Agree a numbering format.

  2. Choose the tag

    On-metal for metal assets; consider heat, chemicals, washing and how the tag will be fixed.

  3. Tag and register

    Fix each tag and read it once to link the number to the asset.

  4. Audit

    Walk the site with a handheld reader and compare with the register.

  5. Add fixed readers where it pays

    At a door or tool counter, to record movements automatically.

Before you deploy

  • Test on curved, painted or recessed metal; they change the range.
  • Test with your own items, tags and readers before ordering volume.
Specifications

Confirmed Specifications

Chip / ICNXP U8
Frequency902-928mhz or 865-868mhz
Protocol / StandardEPC Class1 Gen2/ISO 18000-6C
MemoryEPC 128bits,
Read range3-5m(On Metal)
Size80mm*58mm*3mm
MaterialAviation leather,can be used outdoors for 3-5years
Operating temp-20°C to 80°C
Waterproof / IPIP68
MountingIndustrial grade adhesive binding, sewing, riveting

Need a value that is not listed? Ask in the form and our engineers will confirm it for your order.

Ordering

Samples, MOQ & Lead Time

MOQ50 pieces
Sample policyFree samples available
Sample quantity1–2 pcs (Free)
Sample lead time5-7 days
PricingQuoted per project and quantity. Send your quantity and requirements in the form.
Customization

Printing & Encoding

Printing & brandingCustomized logo,QR code, Serial No.
Product Details

See the Product Up Close

Selected technical, installation and application media for this product.

FAQ

Common Questions

Why does an ordinary tag fail on metal?

Metal reflects the signal and detunes the tag's antenna, which can cause poor range, phantom reads, or no read at all. On-metal tags put a spacer between the antenna and the metal, or use a special antenna design.

Do I need a special reader?

No. Standard UHF readers read on-metal tags, as long as they are on the same radio band and follow the standard (EPC Gen2).

How do I fix the tag?

Use adhesive on clean flat metal, or screws or rivets where the asset is cleaned, vibrates or is handled roughly.

How far can it be read?

The range depends on the tag, the metal, the reader and the antenna. Test on your real assets.

What is the minimum order quantity for the Gas Cylinder UHF RFID On-Metal Tag, 80*58*3mm?

The minimum order quantity is 50 pieces. Before bulk production we can send 1–2 pcs (Free) for testing.

Can I get samples before placing an order?

Free samples available. Sample quantity: 1–2 pcs (Free). Samples are ready in 5-7 days.

Can you print our logo and encode the chips?

Printing and customization: Customized logo,QR code, Serial No..

Last updated:

Get Started

Ready to Test Samples?

Tell us your quantity, application and delivery country. We reply within 24 hours.

Engineering Samples 1–2 pcs Free · 24h DHL Dispatch