Home Products About Solutions Resources Contact Get Your Quote
860-960 MHz

RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management

Alien Higgs-3/NXP UCODE8860-960 MHzD18x11mm, D30x11mm or customs

On-metal UHF RFID soft label for metal assets, frequency 860-960 MHz, IP68, with free samples.

10 piece
MOQ
1–2 pcs (Free) · 5-7 days
Samples
0.90m, 902-928MHz(US)0.80m, 865-868MHz(EU)
Read range
ABS Anti-Metal UHF RFID Tag – Hard Tag for Metal Surface Asset Tracking
860-960 MHz
EPC Class 1 Gen 2, ISO18000-6C
Reach, RoHS, CE, ATEX
IP68
Key features

What the RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management does

Main functions

This soft label lets you track metal items with a UHF RFID reader. It works with EPC Class 1 Gen 2 and ISO18000-6C readers. Read range is 0.90m (US) and 0.80m (EU). It is IP68 waterproof and can be screwed onto metal surfaces.

How it works, in plain words

  1. The tag holds a chip with a unique number and is built with a spacer between its antenna and the metal, so metal does not block it as it does an ordinary tag. It has no battery.
  2. A handheld reader (or a reader at a door or tool counter) sends a signal. Every tagged asset in range answers with its number, including those turned away or behind others.
  3. Your asset register links the number to the item: what it is, where it is, who has it, when it was last checked.

What you need to use it

  • The tags (this product), fixed to each asset. Use an on-metal tag where the item is metal.
  • A handheld reader for audits, and optionally a fixed reader at a door or tool counter.
  • An asset register or maintenance system with the list of assets. A simple list is enough to start. Tell us what you use.

What it looks like in your business

Maintenance technician tracking metal toolsReliable tool tracking on metal

Today: Tools go missing because metal surfaces interfere with standard RFID labels. With the product: Attach the soft label to each metal tool with screws. Use a UHF RFID reader to scan tools quickly, even in oily or wet conditions.

What you get: Tools are tracked accurately, reducing loss and search time.

Warehouse manager managing metal containersAccurate inventory of metal containers

Today: Manual counting of metal containers is slow and error-prone. With the product: Screw the labels onto containers. Use a handheld UHF RFID reader to scan multiple containers at once, with read ranges up to 0.90m.

What you get: Faster, more accurate inventory counts.

IT manager tracking metal server racksEfficient server rack tracking

Today: Server racks are difficult to label because metal blocks standard RFID signals. With the product: Mount the soft label on each rack with screws. Use a fixed or handheld UHF RFID reader to identify racks quickly.

What you get: Improved asset visibility and easier audits.

Event staff managing metal equipmentDurable labeling for metal equipment

Today: Equipment gets lost or mixed up during events, and labels often fail. With the product: Attach the IP68 waterproof labels to metal equipment. Use a UHF RFID reader to check items in and out.

What you get: Better equipment accountability and reduced losses.

Before you orderTest on your real metal and your real reader

Today: a data-sheet range is trusted, and then the tag reads poorly on painted or curved metal. With the tag: order a sample, fix it on a real asset in its real position, and read it with your handheld. Check the range and the angle, then order volume.

What you get: A tag proven on your metal.

At a glance

  • Chip: Alien Higgs-3/NXP UCODE8
  • Memory: EPC 96bits(up to 480bits), User 512bits, TID 64bits
  • Read range: 0.90m, 902-928MHz(US)0.80m, 865-868MHz(EU)
  • Durability: IP68
  • Operating temperature: -50℃~260℃
  • Installation: Screw
RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management detail 1RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management detail 2
How it works

How to Use It in Your System

System setup

The hardware and software that work with the RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management in a typical project.

  1. 1Tags (this product)

    Fixed to each asset.

  2. 2Reader

    Handheld for audits; optionally fixed at a door or counter.

  3. 3Asset register

    Holds what each number means.

  4. 4Audit

    Compare what is read with what the register expects.

Installation and daily use

  1. List what to tag

    Choose assets that are lost, shared or need inspection. Agree a numbering format.

  2. Choose the tag

    On-metal for metal assets; consider heat, chemicals, washing and how the tag will be fixed.

  3. Tag and register

    Fix each tag and read it once to link the number to the asset.

  4. Audit

    Walk the site with a handheld reader and compare with the register.

  5. Add fixed readers where it pays

    At a door or tool counter, to record movements automatically.

Before you deploy

  • Test on curved, painted or recessed metal; they change the range.
  • Test with your own items, tags and readers before ordering volume.
Specifications

Confirmed Specifications

Chip / ICAlien Higgs-3/NXP UCODE8
Frequency860-960 MHz
Protocol / StandardEPC Class 1 Gen 2, ISO18000-6C
MemoryEPC 96bits(up to 480bits), User 512bits, TID 64bits
Read range0.90m, 902-928MHz(US)0.80m, 865-868MHz(EU)
SizeD18x11mm, D30x11mm or customs
Material304 Stainless Steel/Metal
Operating temp-50℃~260℃
Waterproof / IPIP68
MountingScrew
CertificationsReach, RoHS, CE, ATEX

Need a value that is not listed? Ask in the form and our engineers will confirm it for your order.

Ordering

Samples, MOQ & Lead Time

MOQ10 piece
Sample policySamples available
Sample quantity10-20 pcs
Sample lead time5-7 days
PricingQuoted per project and quantity. Send your quantity and requirements in the form.
Product Details

See the Product Up Close

Selected technical, installation and application media for this product.

FAQ

Common Questions

Why does an ordinary tag fail on metal?

Metal reflects the signal and detunes the tag's antenna, which can cause poor range, phantom reads, or no read at all. On-metal tags put a spacer between the antenna and the metal, or use a special antenna design.

Do I need a special reader?

No. Standard UHF readers read on-metal tags, as long as they are on the same radio band and follow the standard (EPC Gen2).

How do I fix the tag?

Use adhesive on clean flat metal, or screws or rivets where the asset is cleaned, vibrates or is handled roughly.

How far can it be read?

The range depends on the tag, the metal, the reader and the antenna. Test on your real assets.

What is the minimum order quantity for the RFID Tag High Temperature Screw Tag, φ18mm, 260°C, Stainless Steel UHF Screw for Oil Drilling Drill Pipe Management?

The minimum order quantity is 10 piece. Before bulk production we can send 10-20 pcs for testing.

Can I get samples before placing an order?

Samples available. Sample quantity: 10-20 pcs. Samples are ready in 5-7 days.

Last updated:

Get Started

Ready to Test Samples?

Tell us your quantity, application and delivery country. We reply within 24 hours.

Engineering Samples 1–2 pcs Free · 24h DHL Dispatch